Details
-
MachineLinker ID ML-25503
-
Manufacturer Tecninox
-
Model Fermenter
-
Machine type Fermenter
-
Year of manufacture 2015
-
Condition As good as new (ex-display)
-
Category Process vessels and paste kettles
Technical data
- Fermenter geometry3:1
- Operational pressure range-0.01 to 3. 00 bar g
- Configurable motor speed50-1500 rpm
- Motor positionoverhead motor shaft, as close as possible to sparger and bottom
- Working volume for 36L bioreactor20L, Minimum working volume 7.5L (positioning holder for probes)
- Working volume for 74L bioreactor50L, dependent on position of last impeller
- Aeration0 to 2. 5 VVM
- O2 inlet0 to 2.5 VVM, O2 inlet from above and from the sparger, with flowmeter
- N2 inlet0 to 1 VVM, N2 inlet from above and from the sparger, with flowmeter
- CO2 inlet0 to 1 VVM, CO2 inlet from above and from the sparger, with flowmeter
- Head pressure adjustmentautomatic
- Integrity testintegrated housing to perform in situ integrity test
- Electricity380v, 50Hz
- Steam feed3 – 9 bar
- Clean steam3 bar g
- Compressed air8 bar g
- Refrigerated water9 – 12 deg C
- Nitrogen8 bar
- Oxygen12 bar
- CO28 bar
Description
TECNinox fermenter/bioreactor
Year of construction: 2015
Suitable for R&D, small batch production, pilot plant. Box of manuals included.
Characteristics:
- Fermenter head without sharp edges to improve cleaning, GMP gasket; with TC connections of various sizes (3/4, ½, 1), usable for additions, feeding, inoculation, etc.
- Fermenter geometry: 3:1
- Operational pressure range: -0.01 to 3. 00 bar g
- Double mechanical seal
- Impellers 3 Rushton / 3 Pitched Blade
- Configurable motor speed: 50-1500 rpm
- Motor position: overhead motor shaft, as close as possible to sparger and bottom
- Toroidal sparger with possibility of coupling and uncoupling
- Exhaust gas condenser
- Integrated CIP system
- Working volume for 36L bioreactor: 20L, Minimum working volume 7.5L (positioning holder for probes)
- Working volume for 74L bioreactor: 50L, dependent on position of last impeller
Exhaust gas management: double exhaust gas line after the outlet filter (the gas line must divide into two branches: one direct to the spent gas analysis system (airnova) and the other to the drain/waste)
Inlet air from above and from the sparger, with flowmeter
Aeration: 0 to 2. 5 VVM
O2 inlet: 0 to 2.5 VVM, O2 inlet from above and from the sparger, with flowmeter
N2 inlet: 0 to 1 VVM, N2 inlet from above and from the sparger, with flowmeter
CO2 inlet: 0 to 1 VVM, CO2 inlet from above and from the sparger, with flowmeter
- Head pressure adjustment: automatic
- Fixed speed pump with remote control
- Bottom valve filter
- Variable speed pumps, two bottom valves
Integrity test: integrated housing to perform in situ integrity test
Loading soil hole for manual loading
Fixed speed Peristaltic pumping, position adjacent to bioreactor pH, for control of acid/ base, CO2
Feeding base inlet via Sacova valve with ingold control
Requirements:
Electricity: 380v, 50Hz
Steam feed: 3 – 9 bar
Clean steam: 3 bar g
Purified water
Compressed air: 8 bar g
Refrigerated water: 9 – 12 deg C
Nitrogen: 8 bar
Oxygen: 12 bar
CO2: 8 bar
Softened water
Drainage and discharge
Machine location
Open on Google Maps-
Address: Via Don L. Guanella 1/E
-
City: Bologna
-
Zip/Postal code: 40141
-
Country: Italy